Today we’re installing a 3kW laser cutting machine, a 3kW Tongfei Chiller, and a 3kW Raycus Laser. For users considering similar setups, exploring options like the laser cutting machines can help you choose the right configuration for your workspace.
This is the power cable for the chiller, which needs to be connected to 380V power. These are the two cooling water lines for the laser source, and these are the two cooling water lines for the cutting head: water inlet and water outlet. This is the laser machine’s power plug; plug it in until you hear a click—one inlet and one outlet. This is the optical cable, this is the network cable, and this is the control signal cable.
Now start the installation. The blue hose is generally connected to the outlet. First, put on the hose clamp. You can wiggle it slightly to help with installation. Connect the outlet of the chiller to the inlet of the laser. Remove the protective cover. After putting on the hose clamp, connect the hose. If it’s hard to tighten, use a lever to apply a bit more force, but don’t make it too tight, as overtightening may damage the clamp. Make sure there are no gaps at the hose connection and place the clamp next to the joint. The outlet connection is now complete.
If your production requires frequent plate changes, you might prefer a laser cutting machines, which enhances workflow efficiency during multi-batch operations.
The inlet of the chiller is usually connected to a red hose. This is the inlet for low-temperature water, also called the return port, and is usually connected with a red hose. After putting on the hose clamp, install it, ensuring there are no gaps at the hose connection. Connect the inlet of the chiller to the outlet of the laser. After putting on the hose clamp, install it and tighten the hose clamp. If it’s hard to tighten, use a lever to apply a bit more force.
These are the two cooling water pipes coming from the cutting head. The blue hose is generally connected to the high-temperature outlet, and the red hose is connected to the inlet, also called the return port. Push it in tightly.
For the 3kW Raycus Laser, connect the power cable, control signal cable (tighten the two screws), and network cable. This is the outlet, and this is the inlet. This is the water inlet of the 3kW Tongfei chiller. It is recommended to add 14 liters of distilled water. Unscrew the water inlet cap. Since the inlet is relatively low, pour the water slowly. Fill the water up to between the blue and red lines, preferably closer to the blue line. After turning on the laser, some water will be used up. After filling the water, screw the cap back on.
To explore more technical specifications or product options, you can refer to our brochures. For personalized consultation or after-sales support, feel free to contact ZWCNC directly.
Apply this guidance to your production
Share your material, thickness, part drawing, tolerance, and target output with the ZWCNC engineering team for an application-specific equipment review.
More news, insights, and updates from ZWCNC.

How to Install the Hanli Water Chiller for a Laser Cutting Machine

How to Install the Water Chiller for the Laser Cutting Machine

How to Install the BOCI Laser Cutting Head

How to Clear the Water Level Alarm of the Laser Cutting Machine

How to Resolve the High-Temperature Water Flow Alarm on a Laser Cutting Machine