The water chiller is currently showing an Er06 alarm. You can scan the QR code with your phone. Er06 indicates a high-temperature water flow alarm. At this point, you need to check whether the high-temperature water circuit is blocked or connected incorrectly. Begin troubleshooting. Both circuits seem fine on inspection. Trace along the water pipes. Found that the piping here is kinked. It needs to be straightened. If your chiller is connected to laser cutting equipment such as a laser cutting machines, maintaining smooth water flow is especially critical to ensure optimal cutting quality.
If the alarm is not cleared, turn off the machine and restart it. Then turn it back on. The alarm is cleared. For production environments operating multiple laser systems, such as those using a laser cutting machines, it’s important to regularly inspect your cooling units to prevent downtime.
If during operation the water chiller triggers Er06 or Er08 alarms, at this time, clean the filters on both sides of the water chiller. Excessive dust on the filters can seriously affect heat dissipation. First, turn off the machine. Now remove the filters. Lift upwards first, then pull up and out, and it's removed. Blow off the dust with an air gun or wash it clean with water. After cleaning, reinstall it back. Install the top first, then lower it into place. Similarly, clean the filter on the other side. Lift it upwards, pull it outwards. Blow off the dust with an air gun or wash it clean with water. After cleaning, reinstall it back. Install the top first, then lower it into place. That completes the process.
For further maintenance advice or detailed operation documents, you may download our latest brochures. If you need customized cooling solutions for specific laser equipment, please contact ZWCNC for professional technical support.
Apply this guidance to your production
Share your material, thickness, part drawing, tolerance, and target output with the ZWCNC engineering team for an application-specific equipment review.
More news, insights, and updates from ZWCNC.

How to Prevent Burn Marks During Laser Cutting: A Troubleshooting Guide

Fiber Laser Cutting Machine Maintenance Checklist and Schedule

Fiber Laser Cutting Machine Maintenance, Safety, and Troubleshooting

Laser Cutting Problems and Solutions: Fast Defect Diagnosis

Fiber Laser Cutting for HVAC Ductwork: Throughput, Quality, and ROI