ZWCNC TECHNICAL ARCHIVE

ESTUN E21S Shearing Controller Operation Reference

A version-specific map of E21S backgauge, cut-angle, cut-gap and stroke control, single- and multi-step programs, manual movement, alarms, backup/restore and common troubleshooting.

ESTUN E21SV1.06, 5 March 2015Controller operation reference

What this reference covers

  1. 1Panel keys, display zones and abbreviations
  2. 2Single-step and multi-step programs
  3. 3Backgauge, angle, gap and delay parameters
  4. 4Manual movement and reference search
  5. 5Alarm records and common-fault checks

Field verification checklist

Confirm whether A- and G-axis control is installed on the machine
Do not exceed the shear capacity shown on the machine nameplate
Back up working programs before restore operations
Keep clear of the backgauge and blade zone during manual movement
Record the complete alarm and state before power cycling

Continue with related engineering resources